COMBINED AND HIGH-PITCHED CABLE OF THE LOCAL COMMUNICATION KSPP OG, KSPP OGP, KSPPOZ
◄This type of product is always under the order, except for the cable presented in the offer. When ordering, please pay special attention to the item "MARKING CABLE WHEN ORDERING", which you will find below on the page. | |
◄ Product and price information |
FUNCTION KSPPog – the cables that are used to lay cable channels, in plastic pipes, under bridges and ramps. |
|||
The description of KSPPog
1. A glass and plastic bar
2. AN optical module Ø2,1 mm 3. A hydrophobic gel 4. Optical fibers 5. Polyethylene insulation of conductor Ø2,1 mm 6. A copper conductor Ø0,9 – 1,2 mm 7. A waterproof filling material 8. A polyethylene jacket with thickness of 0,8 mm 9. A tinned wire Ø0,4 mm 10. A PE band 11. A steel laminated tape 12. A polyethylene jacket with thickness of 2,0 mm |
|||
The description of KSPPogp 1. A glass and plastic bar |
|||
The description of KSPPoz 1. A glass and plastic bar 2. AN optical module Ø2,1 mm 3. A hydrophobic gel 4. Optical fibers 5. Polyethylene insulation of conductor Ø2,1 mm 6. A copper conductor Ø0,9 – 1,2 mm 7. A waterproof filling material 8. A polyethylene jacket with thickness of 0,8 mm 9. A tinned wire Ø0,4 mm 10. A PE and aluminum tape 11. A polyethylene jacket with thickness of 2,0 mm |
Design 1.The central power element – a glass-plastic rod or a steel rope |
Service and assembly conditions 1. Temperature – from -40°C to +50°C |
Specifications 1. Cable outside diameter(with the construction) – 14,8/17,0 (mm) |
Specifications:
The diameter of a current-carrying conductor, mm | 0,9 | 1,02 | |
Electrical resistance of a current-carrying conductor,counted for 1 km of length and for a temperature of 20C, Om, not more |
28,4 | 15,8 | |
Electrical resistance of insulation of a current-carrying conductor , counted for 1km of length and for a temperature of 20C, Mom, not less | 15000 | 15000 | |
Coats | 5 | 5 | |
Working capacity, counted for 1km of length, nF | 35±3 | 43,5±3 | |
Electrical resistance of the screen, counted for 1 km of length and for a temperature of 20C, Om, not more | 15 | 15 | |
Transitive attenuation between cable circuits on the near end, counted for the length of 750m at a digital influencing signal in the form of pseudo-random sequence(PSP), not less, dB -at a transfer speed of 1024kb/s -at a transfer speed of 1024kb/s |
64 59 |
64 59 |
|
Protectability between cable circuits on the farther end, counted for a length of 750m, not less, dB | 45 | 45 | |
An attenuation constant, dB/km, not more: - at a frequency of 512khz - at a frequency of 1024khz |
6,9 7,5 |
6,9 7,5 |