COMBINED AND HIGH-PITCHED CABLE OF THE LOCAL COMMUNICATION KSPP OG, KSPP OGP, KSPPOZ

This type of product is always under the order, except for the cable presented in the offer. When ordering, please pay special attention to the item "MARKING CABLE WHEN ORDERING", which you will find below on the page. CONFIGURATION AND ORDER
  DOWNLOAD OFFER
 Product and price information ASK  
We also invite you to visit our online store at:
 

FUNCTION

KSPPog – the cables that are used to lay cable channels, in plastic pipes, under bridges and ramps.
KSPPogp – the cables that are used for hooking on poles of communication lines, on overhead system of railway
and on lamp-posts.
KSppoz – the cables that are used for laying in protective plastic pipes.

The description of KSPPog
1. A glass and plastic bar
2. AN optical module Ø2,1 mm
3. A hydrophobic gel
4. Optical fibers
5. Polyethylene insulation of conductor Ø2,1 mm
6. A copper conductor Ø0,9 – 1,2 mm
7. A waterproof filling material
8. A polyethylene jacket with thickness of 0,8 mm
9. A tinned wire Ø0,4 mm
10. A PE band
11. A steel laminated tape
12. A polyethylene jacket with thickness of 2,0 mm
    

The description of KSPPogp

1. A glass and plastic bar
2. AN optical module Ø2,1 mm
3. A hydrophobic gel
4. Optical fibers
5. Polyethylene insulation of conductor Ø2,1 mm
6. A copper conductor Ø0,9 – 1,2 mm
7. A waterproof filling material
8. A polyethylene jacket with thickness of 0,8 mm
9. A tinned wire Ø0,4 mm
10. A PE and aluminum tape
11. Aramide fibers
12. A polyethylene jacket with thickness of 1,8 mm

   

The description of KSPPoz
1. A glass and plastic bar
2. AN optical module Ø2,1 mm
3. A hydrophobic gel
4. Optical fibers
5. Polyethylene insulation of conductor Ø2,1 mm
6. A copper conductor Ø0,9 – 1,2 mm
7. A waterproof filling material
8. A polyethylene jacket with thickness of 0,8 mm
9. A tinned wire Ø0,4 mm
10. A PE and aluminum tape
11. A polyethylene jacket with thickness of 2,0 mm
 

Design

1.The central power element – a glass-plastic rod or a steel rope
2. Modules with optical fibers
3. An intramodule waterproof filling material
4. Fujikura, Corning, Draka optical fibers
5. PE insulation of a conductor
6. A current-carrying copper conductor Ø0,9 – 1,2 mm
7. An intermodule waterproof filling material
8. A PE jacket
9. A tinned wire
10. A PE and aluminum tape
11. The armour from the steel goffered band with 2 side polymeric coating
12. A protective hose from polyethylene

Service and assembly conditions

1. Temperature – from -40°C to +50°C
2. The cables must be laid and installed by hand and mechanically at a temperature of not lower than -10°C
3. During the installation and use an acceptable bend is not less than the nominal diameter of the cable
4. The cable service life - not less than 25 years.
5. The cables are resistible to mold, dew, hoarfrost, salt fog, sunshine and to damage by rodent

Specifications

1. Cable outside diameter(with the construction) – 14,8/17,0 (mm)
2. N ominal weight(with the construction) – 184-255 kg/km
3. The cable is resistible to stretching force: KSPPog – 2,7 kH, KSPPogp – 6-10 kH, KSPPoz – 1,0-2,7 kH
4. The cable is resistible to crushing force, not less than – 400 H/cm
5. Attenuation constant at a length of a wave 1550 nm – 0,22 dB/km
6. The total number of fibers is from 4 to 16

Specifications:

The diameter of a current-carrying conductor, mm 0,9 1,02

Electrical resistance of a current-carrying conductor,counted for 1 km of length and for a temperature of 20C, Om, not more

28,4 15,8
Electrical resistance of insulation of a current-carrying conductor , counted for 1km of length and for a temperature of 20C, Mom, not less 15000 15000
Coats 5 5
Working capacity, counted for 1km of length, nF 35±3 43,5±3
Electrical resistance of the screen, counted for 1 km of length and for a temperature of 20C, Om, not more 15 15
Transitive attenuation between cable circuits on the near end, counted for the length of 750m
at a digital influencing signal in the form of pseudo-random sequence(PSP), not less, dB
-at a transfer speed of 1024kb/s
-at a transfer speed of 1024kb/s
64
59
64
59
Protectability between cable circuits on the farther end, counted for a length of 750m, not less, dB 45 45
An attenuation constant, dB/km, not more:
- at a frequency of 512khz
- at a frequency of 1024khz
6,9   
7,5
6,9
7,5

 

}