of OMZKGC (A-ВDF2Y-2...144E9/125), OMZKGCN types

This type of product is always under the order, except for the cable presented in the offer. When ordering, please pay special attention to the item "MARKING CABLE WHEN ORDERING", which you will find below on the page. CONFIGURATION AND ORDER
  DOWNLOAD OFFER
 Product and price information ASK  
We also invite you to visit our online store at:
 

FUNCTION:
The cable is designed for installation in grounds of all categories, except for damaged by frozen deformations, in cable duct, tubes, blocks, collectors, tunnels on bridges and in mines, through shallow swamps and unnavigable rivers.

    
1 - Optical fibre
2 - Hydrophobic compound
3 - Central tube
4 - Hydrophobic compound
5 - Steel wire
6 - Jacket
 

DESIGN

1.    Optical fibre produced by Fujikura, Corning, Draka
2.    Hydrophobic filling in the module
3.    Module - central tube from polybutyleneterephthalate
4.    Hydrophobic filling between armour and module
5.    Armour from circular steel corrugated wires
6.    Jacket from polyethylene

SERVICE AND ASSEMBLY CONDITIONS

1.    Operating temperature range - from -40°C to 70°C
2.    The cables are designed for mechanized and manual installation at a temperature not lower than -10°C
3.    Admissible bending radius during assembly not less than 20 nominal cable diameters during operation and not less than 250 mm during installation and assembly
4.    The cables' service life, not less than - 25 years
5.    The cables are resistant to mold fungi, dew, rain, frost, salt fog, solar radiation, and damage by rodents

 

SPECIFICATION

1.    Outside diameter of the cable (depending on design), -10,6 -13 (mm)
2.    Nominal weight (depending on design) - 218 - 238 (kg/km)
3.    The cable is tensile stress resistant, - from 4,0 to 20,0 (kN)
4.    The cable is crushing stress resistant, not less than -1000 N/cm
5.    Attenuation constant, on 1550 nm wavelength - 0,21 dB/km
6.    Total number of fibres-from 4 to 16
7.    Electrical resistance of outside sheath (armour - ground) not less than 2000 MOhm/km

 

MARKING CABLE WHEN ORDERING

OMZKGC-10-01-0,22-4...144 (8,0) optical long-distance intraareal cable:
O-for optical, M-for long-distance, Z-for areal, K-for duct, G-for ground,
C-for single-module, 10-diameter of mode field, 01- central tube from polybutyleneterephthalate, 0,22-attenuation constant, 4...16-number of fibres, 8,0-admissible tensile stress.
OMZKGCN-10-01-0,22-4...144 (8,0) cables in non-combustible design, sheath from a material not spreading combustion.

REGULATIONS

TU 16.К87-001-00

 

 

}

TOP PAGES

uCoz