SIP-1 (AMKA AXKA NFA2X SAX ABC)
◄This type of product is always under the order. When ordering, please pay special attention to the item "Specifications", which you will find below on the page. | |
◄ Product and price information |
1. SIP-1 (AMKA AXKA NFA2X SAX ABC) |
||
FUNCTION: Self-supporting shielded wire designed for trunks of overhead transmission lines and line branching from overhead transmission lines in the atmosphere of air types I and II according to State Standard 15150-69. |
||
DESIGN:
|
||
SERVICE AND ASSEMBLY CONDITIONS: Admissible heating of conductor during operation in normal conditions – not over 90°CAdmissible heating of conductor in case of a short circuit – not over 250°C Environment temperature, from -60 to 50°C It is recommended to carry out assembly at an environment temperature not lower than 20°C Bending radius during assembly – not less than 10 diameters of the wire Service life – 40 years Warranty period – 3 years |
||
REGULATIONS: TU 16-705.500-2006; TU BY 400424686.006-2008 | ||
2.SIP-2(AMKA AXKA NFA2X SAX ABC) |
||
FUNCTION: Self-supporting shielded wire with current-carrying conductor from aluminium alloy designed for trunks of overhead transmission lines and line branching from overhead transmission lines in the atmosphere of air types I and II according to State Standard 15150-69, including seashores, salinas, |
||
DESIGN:
|
||
SERVICE AND ASSEMBLY CONDITIONS: Admissible heating of conductor during operation in normal conditions – not over 90°CAdmissible heating of conductor in case of a short circuit – not over 250°C Environment temperature, from -60 to 50°C It is recommended to carry out assembly at an environment temperature not lower than 20°C Bending radius during assembly – not less than 10 diameters of the wire Service life – 40 years Warranty period – 3 years |
||
REGULATIONS: TU 16-705.500-2006; TU BY 400424686.006-2008 | ||
3. SIP-3 (AMKA AXKA NFA2X SAX ABC) |
||
FUNCTION: The wire is designed for overhead transmission lines at nominal voltage 10-35 kV in the atmosphere of air types I and II according to State Standard 15150-69, including seashores, salinas, industrial regions and areas with saline sands. |
||
DESIGN:
|
||
SERVICE AND ASSEMBLY CONDITIONS: Admissible heating of conductor during operation in normal conditions – not over 90°CAdmissible heating of conductor in case of short circuit – not over 250°C Environment temperature, from -60 to 50°C It is recommended to carry out assembly at an environment temperature not lower than 20°C Bending radius during assembly – not less than 10 diameters of the wire Service life – 40 years Warranty period – 3 years |
||
REGULATIONS: TU 16-705.500-2006; TU BY 400424686.006-2008 | ||
4. SIP-4 (AMKA AXKA NFA2X SAX ABC) |
||
FUNCTION: Self-supporting wire without carrier element, designed for overhead transmission lines branching to the lead-in and for installation on the walls of buildings and engineering structures in the atmosphere of air types I and II according to State Standard 15150-69. |
||
DESIGN:
|
||
SERVICE AND ASSEMBLY CONDITIONS: Admissible heating of conductor during operation in normal conditions – not over 90°CAdmissible heating of conductor in case of a short circuit – not over 250°C Environment temperature, from -60 to 50°C It is recommended to carry out assembly at an environment temperature not lower than 20°C Bending radius during assembly – not less than 10 diameters of the wire Service life – 40 years Warranty period – 3 years |
||
REGULATIONS: TU 16-705.500-2006; TU BY 400424686.006-2008 | ||
5. WIRE OF TYPE A (AAC ) |
||
FUNCTION: Electricity transmission in overhead electrical networks on the grounds of all macroclimatic regions with moderate and frigid climate. |
||
DESIGN:
|
||
SERVICE AND ASSEMBLY CONDITIONS: Installation is carried out in the air on the supports of power lines in compliance with technical operation instructions of electrical installations electric power plants and networks. |
||
REGULATIONS: State Standard 839-80 | ||
6. WIRE OF TYPE AC (ACSR) |
||
FUNCTION: Electricity transmission in overhead electrical networks on the grounds of all macroclimatic regions with moderate and frigid climate. |
||
DESIGN:
|
||
FEATURES: The peculiarity of wires of AC type is that there’s a central carrier core from a single or twisted steel |
||
SERVICE AND ASSEMBLY CONDITIONS: Installation is carried out in the air on the supports of power lines in compliance with technical operation instructions of electrical installations electric power plants and networks. |
||
REGULATIONS: State Standard 839-80 |